메뉴 건너뛰기

Sub Promotion

TG210 NDIR Refrigerant R32(CH2F2) Sensor

Compact size NDIR R32 sensor (56 × 42 ㎜)

Wide detection range(0~30,000ppm)

Fast Response time(20~28 sec)

Various output (UART, I2C, Analog Out)

Accurate and Long-term Stability

Low temperature working(-20~50℃)

DOWNLOAD DATASHEET

APPLICATION

The TG210 measuring refrigerant R32 is a NDIR (Non-Dispersive Infrared) gas sensor. As it is contactless, it has high accuracy and longer life, than other sensors. This sensor has been developed with standard gas and is efficiently calibrated using our state of the art gas sensor calibration technology. Furthermore, this sensor comes with Serial (UART), I2C interface and Analog Output for user.

General Performance

Operating Temperature range : -20 ~ 50℃

Operating Humidity range : 0 ~ 95% RH (Non-condensing)

Storage Temperature : -30℃ ~ 70℃

Electrical

Power Supply Requirements : 5 VDC regulated (±0.25V)

Power Consumption : Normal : 15~24mA, Max : 220mA at Lamp on Peak

Interface

UART : 38,400bps, 8bit, No Parity, 1 Stop bit, TTL Level 3.3V or 5.0V

I2C : Slave Mode, Internal Pull-Up Resister, Under 400KHz (TTL Level 3.3V)

Analog Out : VDC 10mV~4,000mV (100ppm=13mV)